Dump because application log instance is initial

[] [] [] []

Symptom
The MDRO execution dumps if an error occurs during creation of execution
node.
Other terms
MDRO, MDRO scheduling, application log
Reason and Prerequisites
This issue affects Business ByDesign FP2.0 SPS 0, SPS1 and SPS2.
Solution
The issue is fixed with a hotfix for Business ByDesign FP2.0 SPS0 (H0EK008167), FP2.0 SPS1 (H1EK003937) and a correction for FP2.0 SPS2(MGGK031974)

Health check for check ITSAM_JOBSCHED 00008 fails

[] [] [] [] [] [] [] [] []

Symptom
When the health check ITSAM_JOBSCHED 00008 “wrong MDRO status” is performed, the ABAP runtime error CONVT_NO_NUMBER, CX_SY_CONVERSION_NO_NUMBER is raised in program CL_MDRO_HEALTH_CHECK==========CM001 line 962.
Other terms
MDRO, Execution, Job Counter, Background Job, Processing Status, Application Log
Reason and Prerequisites
When the attribute job counter of an MDRO execution contains at least one character, the above mentioned runtime error [...]

Application Log: Formatted ID of MDRO Execution wrong

[] [] []

Symptom
The formatted ID of the run execution is not display correctly in the header section of the Application Log. Only the run execution ID is shown, not the formatted ID of the run execution.
Other terms
MDRO, Application Log
Reason and Prerequisites
Root cause for this issue is that the formatted ID is not set correctly in [...]

Requester’s assigned workcenters doesn’t work in FP2.0 sp0

[] [] [] [] [] [] [] [] []

Symptom
In portal of FP2.0 sp0 systems, when go to “Application Management” workcenter, edit an incident, click the tab “Incident Context”, there is a dump occured in the ABAP backend.
And the Requester’s Assigned Workcenters are empty.
Other terms
Application Management Workcenter, Incident Context
Reason and Prerequisites
The is a bug in SP0. It has been fixed it in SP1.
The [...]

FS application activeness check wrong in BUA_ADDRESS_XPRA_TD

[] [] [] [] [] [] [] [] []

Symptom
The check for FS application activeness is wrong in the function module BUA_ADDRESS_XPRA_TD.
Other terms
BUA_ADDRESS_XPRA_TD, LBUPA_TD_SWITCHF03, fs_check, FSBP_CHECK_FS_CRITERIA, gv_fs_active
Reason and Prerequisites
In the function module BUA_ADDRESS_XPRA_TD, there is a check to determine whether FS application is active in the system. The result is ‘J’ if FS is active, ‘N’ if FS is inactive. But the [...]

BP: Removal of CL_CMD_APPLLOG=>GET_SINGLETON_INSTANCE usages

[] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] [] []

Symptom
Obsolete instance handling of application log (CL_CMD_APPLLOG) in BankDetails- and PaymentCardDetails-IPI has to be swapped to the new concept.
Other terms
BUSINESS_PARTNER_TMPL, BUSINESS_PARTNER, BANK_DETAILS, PAYMENT_CARD_DETAILS, BuPa, Business Partner, CL_CMD_APPLLOG, application log, GET_SINGLETON_INSTANCE, CL_BUP_CARD_1, CL_BUP_BANK_ESA, CONSTRUCTOR, CL__BUP_TRANSACTION_PARTNER, different instances of application log in AUnit-scenarios
Reason and Prerequisites
With this correction this functional adaptation is done as required [...]